Úsáidtear an trealamh seo chun pataiginí riospráide cliniciúla coitianta a bhrath in vitro i sputum daonna, lena n -áirítear Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter Baumannii (ABA), Pseudomonas aeruginosa (PA) Stenotrophomonas Maltophilia (SMET), Bordetella pertussis (BP), Bacillus parapertusss (BPP), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (CPN), Legionella pneumophila (Leg). Is féidir na torthaí a úsáid mar chúnamh i ndiagnóisiú othar a bhfuil an t -ospidéal nó an drochthionchar orthu le hionfhabhtuithe baictéaracha amhrasta sa chonair riospráide.Úsáidtear an trealamh seo chun pataiginí riospráide cliniciúla coitianta a bhrath in vitro i sputum daonna, lena n -áirítear Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter Baumannii (ABA), Pseudomonas aeruginosa (PA) Stenotrophomonas Maltophilia (SMET), Bordetella pertussis (BP), Bacillus parapertusss (BPP), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (CPN), Legionella pneumophila (Leg). Is féidir na torthaí a úsáid mar chúnamh i ndiagnóisiú othar a bhfuil an t -ospidéal nó an drochthionchar orthu le hionfhabhtuithe baictéaracha amhrasta sa chonair riospráide.


Sonraí Táirgí

Clibeanna Táirgí

Ainm an táirge

HWTS-RT162A 11 Cineál Kit Braite Aigéad Núicléasach Pataigine Riospráide(PCR Fluaraiseachta)

Cumhacht

靶标 Cumhacht
核酸反应液 a 核酸反应液 b 核酸反应液 c 核酸反应液 D.
HI Perma MP Cos Fear
SP PA Bp / Cy5
Kpn Aibáí BLP CPN Rx
内参 内参 内参 内参 Vic/Hex

Eipidéimeolaíocht

Is aicme thábhachtach de ghalair iad ionfhabhtuithe conaire riospráide a chruthaíonn bagairt thromchúiseach do shláinte an duine, agus léirigh staidéir go bhfuil an chuid is mó de na hionfhabhtuithe riospráide mar thoradh ar phataiginí baictéaracha agus víreasacha a dhéanann an t-óstach a ionfhabhtú, rud a fhágann go bhfuil déine níos mó an ghalair agus fiú Bás, mar sin is féidir cóireáil spriocdhírithe a dhéanamh ar an bpataigin a shoiléiriú agus feabhsaíonn sé ráta marthanais an othair[1,2].

Paraiméadair theicniúla

Stóráil

≤-18 ℃

Suim 12 mhí
Cineál eiseamail Spumall
Ct Hi 、 sp 、 kpn 、 pa 、 aba 、 smet: CT≤33BP 、 BPP 、 MP 、 CPN 、 Leg: CT≤38
CV <5.0%
Lóistín Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, PseudomonasAeruginosa, Acinetobacter Baumannii, Stenotrophomonas Maltophilia agus LegionellaPneumophila: 1000 CFU/ML

Bordetella pertussis agus Bacillus parapertussis: 500 CFU/ML;

Mycoplasma pneumoniae agus chlamydia pneumoniae: 200 cóip/ml.

Sainiúlacht Léirigh na torthaí tástála tras-imoibríochta nach raibh aon tras-imoibriú idir an trealamh seo agus cytomegalovirus, Herpes simplex víreas 1, víreas varicella-zoster, víreas Epstein-Barr, Bordetella pertussis, Corynebacterium , Moraxella Catarrhalis, Attenuated Strains de Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureusus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acineteobacter, BauumAntrilii, StenorasiOnas, MaliLOPASIUS, Acinetobacter, Bainín, Burkholderia Cepacia, Corynebacterium striatum, Nocardia, Serratia Marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, candida albicans, pneellasi, pneella, pneella, pneella, pneella, pneella, pneella, pneella, pNeellaus, pneellasi, pneella, pneellaus, pneellasi, pneellaus, pNeellausus, pneellaus, pneellausus, pneellaus, pneellasusus, pneellasusus, pneellasus, pneellas, Chlamydia psittaci, Coxiella burnetii agus aigéid núicléasacha géanómacha daonna.
Ionstraimí infheidhme BioSystems Feidhmeach 7500 Córais PCR Fíor-Ama

BioSystems Applied 7500 Córais PCR Fast Fíor-Ama

Cainníocht®5 chóras PCR fíor-ama

Córais PCR fíor-ama SLAN-96P

Solas an tsolais®480 Córas PCR fíor-ama

Linegene 9600 móide córais braite PCR fíor-ama

Cycler teirmeach fíor-ama MA-6000 fíor-ama

Biorad CFX96 Córas PCR fíor-ama

Biorad CFX Opus 96 Córas PCR fíor-ama

Sreabhadh oibre

Macra & Micrea-Thástáil Ghinearálta DNA/RNA Kit (HWTS-3019) (is féidir a úsáid le eastóscóir aigéid uathoibríoch macra agus micrea-thástála (HWTS-3006C, HWTS-3006B)) ag Jiangsu Macra & Micrea-thástáil Medic-Test Tech Co., Ltd.fiseolaíochsalanda go dtí an deascán próiseáilte, agus ba cheart na céimeanna ina dhiaidh sin a dhéanamh de réir na dtreoracha. Is é an méid truaillithe molta ná 100 µl.


  • Roimhe seo:
  • Ar Aghaidh:

  • Scríobh do theachtaireacht anseo agus seol chugainn é